Virtual Lab module · Forward–Reverse
Forward–Reverse with Two Contactors and an Interlock
A 3-phase motor is reversed by swapping two phases through a second contactor. Because the two contactors must never be on together, this circuit trains the electrical interlock.
Complements, and does not replace, practice with physical equipment.

What you practice
- Wire the forward and reverse contactors, three push buttons (forward, reverse, stop), and an overload relay
- Understand how the reverse contactor swaps two phases
- Place the other contactor’s NC contact in the coil path as the interlock
- Check in the Logic tab whether both can energize together
Wiring mistakes it can recognize
Interlock contact missing or in the wrong place
If it is only in the seal-in branch, both contactors can still be on and the Logic tab reports a short circuit.
Both contactors can energize together
The phases are shorted to each other; the behavior finding shows the path.
Incomplete control wiring
The Guide shows which connections are still missing.